Unknown: The behavior of unparenthesized expressions containing both '.' and '+'/'-' will change in PHP 8: '+'/'-' will take a higher precedence in /home/asisen5/public_html/plugins/system/t3/includes/lessphp/less/less.php on line 5085Unknown: The behavior of unparenthesized expressions containing both '.' and '+'/'-' will change in PHP 8: '+'/'-' will take a higher precedence in /home/asisen5/public_html/plugins/system/t3/includes/lessphp/less/less.php on line 7787

Plastic Body


12-Series Dissolved Oxygen Probe

12-Series Dissolved Oxygen Probe

The 12-Series Polarographic DO Probe is a general purpose, lab or field electrode offering reliable polarographic technology and replaceable membrane caps. It provides good performance for many water applications. Features: ABS body with standard 12mm diameter and 120mm length Traditional, polarographic sensor design with silver/platinum cathode/anode Replaceable membrane caps for convenience and economy Suitable for all general purpose or..

G3-Series Dissolved Oxygen Probe

G3-Series Dissolved Oxygen Probe

The G3-Series Galvanic DO Probe is a general purpose, lab or field electrode offering reliable galvanic technology and replaceable membrane caps. It provides good performance for many water applications. Features: ABS body with standard 12mm diameter and 120mm length Popular, galvanic sensor design with lead/silver cathode/anode Replaceable membrane caps for convenience and economy Suitable for all general purpose or advanced applications ..

DOP1-Series Process Optical Dissolved Oxygen Probe

DOP1-Series Process Optical Dissolved Oxygen Probe

The DOP1-Series Process Optical DO Probe offers the latest optical technology in a 4-20mA or 0-5V output for all a variety of continuous measurement applications. It provides full featured performance, a standardized output option, replaceable sensor caps, and long life - all at an affordable price. Features: PVC and stainless steel body with 1" NPT fittings at both ends Popular, cutting-edge, luminescent optical technology Replaceable sensor ca..

DOP2-Series Process Optical Dissolved Oxygen Probe

DOP2-Series Process Optical Dissolved Oxygen Probe

The DOP2-Series Process Optical DO Probe has all the same performance and output as the DOP1-Series Optical DO Probe, but comes in a black, all-PVC body housing for applications where stainless steel is not desirable. Features: Black, all-PVC body housing with 1" NPT fittings at both ends Popular, cutting-edge, luminescent optical technology Replaceable sensor caps and precalibrated convenience Suitable for all dissolved oxygen measurement..

DOL1-Series DO Measurement System

DOL1-Series DO Measurement System

ASI’s DOL1 Optical Dissolved Oxygen Test System offers the latest in dissolved oxygen measurement technology as a complete test capability (meter and probe) at an affordable price. This technology is based on the proven method whereas oxygen concentration is determined by the luminescent quenching of a dye embedded on the sensor surface. Unlike polarographic or galvanic sensors, this optical sensor does not require filling solutions, nor a ..

T025-Series Temperature Probe

T025-Series Temperature Probe

The T025-Series Temperature Probe is a general purpose, lab/field temperature measuring probe offering affordable performance for many water applications. Features: Stainless steel probe with santoprene (rubber) handle/cap. 4mm diameter and 120mm length Many temperature sensor and cap color options available Fast response time Suitable for all general purpose applications ..

43-Series Nitrate Ion-Selective Electrode (ISE)

43-Series Nitrate Ion-Selective Electrode (ISE)

The 43-Series Nitrate Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance nitrate analysis performance for many water applications such as drinking water, agriculture applications and food/beverage. Specifications: Sensor Type: PVC Membrane Range: 0.4-62,000 ppm (as NO3-) Sample pH Range: 2.5-11 Slope: 55 ± 3 mV/ decade Interferences: ClO4-, I-, ClO3-, F- Features: ABS plastic bo..

44-Series Nitrate Ion-Selective Electrode (ISE)

44-Series Nitrate Ion-Selective Electrode (ISE)

The 44-Series Nitrate Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, refillable nitrate analysis performance for many water applications such as drinking water, agriculture applications and food/beverage. Specifications: Sensor Type: PVC Membrane Range: 0.4-62,000 ppm (as NO3-) Sample pH Range: 2.5-11 Slope: 55 ± 3 mV/ decade Interferences: ClO4-, I-, ClO3-, F- Features: Refillable and stan..

12-Series Nitrate Ion-Selective Electrode (ISE)

12-Series Nitrate Ion-Selective Electrode (ISE)

The 12-Series Nitrate Ion-Selective Electrode (ISE) is a premium laboratory or field electrode offering excellent performance and longevity in many water applications such as drinking water, agriculture applications and food/beverage. Specifications: Sensor Type: PVC Membrane Range: 0.4-62,000 ppm (as NO3-) Sample pH Range: 2.5-11 Slope: 55 ± 3 mV/ decade Interferences: ClO4-, I-, ClO3-, F- Features: Refillable reference, replaceable sensor modu..

43-Series Chloride Ion-Selective Electrode (ISE)

43-Series Chloride Ion-Selective Electrode (ISE)

The 43-Series Chloride Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Chloride analysis performance for many water applications. Specifications: Range: 1.8-35,500 ppm Sample pH Range: 2-12 Slope: 56 ± 3 mV/ decade Interferences: CN-, Br-, I-, OH-, S2- must be absent, NH3 Features: ABS plastic body with standard 12mm diameter and 120mm length Sealed, gel-filled double-junct..

44-Series Chloride Ion-Selective Electrode (ISE)

44-Series Chloride Ion-Selective Electrode (ISE)

The 44-Series Chloride Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, refillable Chloride analysis performance for many water applications. Specifications: Range: 1.8-35,500 ppm Sample pH Range: 2-12 Slope: 56 ± 3 mV/ decade Interferences: CN-, Br-, I-, OH-, S2- must be absent, NH3 Features: Refillable and standard 12mm diameter and 120mm length The refillable, double-junction reference g..

03-Series Chloride Ion-Selective Electrode (ISE)

03-Series Chloride Ion-Selective Electrode (ISE)

The 03-Series Chloride Ion-Selective Electrode (ISE) is a general purpose, laboratory electrode offering affordable, refillable Chloride analysis performance for many water applications. Specifications: Range: 1.8-35,500 ppm Sample pH Range: 2-12 Slope: 56 ± 3 mV/ decade Interferences: CN-, Br-, I-, OH-, S2- must be absent, NH3 Features: Refillable and flushable reference in standard 12mm diameter and 120mm length The flushable..

12-Series Chloride Ion-Selective Electrode (ISE)

12-Series Chloride Ion-Selective Electrode (ISE)

The 12-Series Chloride Ion-Selective Electrode (ISE) is a premium laboratory or field electrode offering excellent performance and longevity in many water applications. Specifications: Range: 1.8-35,500 ppm Sample pH Range: 2-12 Slope: 56 ± 3 mV/ decade Interferences: CN-, Br-, I-, OH-, S2- must be absent, NH3 Features: Refillable reference, replaceable sensor modules and standard 12mm diameter and 120mm length The refillable, ..

43-Series Ammonium Ion-Selective Electrode (ISE)

43-Series Ammonium Ion-Selective Electrode (ISE)

The 43-Series Ammonium (NH4) Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Ammonium analysis performance for many water applications. Specifications: Sensor Type: PVC Membrane Range: 0.03-18,000 ppm (as NH4) Sample pH Range: 2-7 Slope: 55 ± 3 mV/ decade Interferences: pH..

44-Series Ammonium Ion-Selective Electrode (ISE)

44-Series Ammonium Ion-Selective Electrode (ISE)

The 44-Series Ammonium (NH4) Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, refillable Ammonium analysis performance for many water applications. Specifications: Sensor Type: PVC Membrane Range: 0.03-18,000 ppm (as NH4) Sample pH Range: 2-7 Slope: 55 ± 3 mV/ decade Interferences: pH..

Showing 16 to 30 of 80 (6 Pages)

Have A Question?

Please let us know your name.
Please let us know your phone number.
Please let us know your email address.
Please let us know your message.
Invalid Input